Model No.:  LW30A-800 Y6300-63

Brand:  HENGFENGYOU

Application:  EHV & UHV Power Transmission and Substation Protection

Phase:  Three-phase

Rated Voltage:  d Substation Protection Rated Voltage:

Rated current:  6300 A

Frequency:  50 Hz / 60 Hz

Degree of protection:  IP55 (Control Cabinet)

Standard:  IEC 62271-100, IEC 62271-1

Certificate:  ISO9001, ISO14001, CE, KEMA / SGS Witness Testing Support

Shell Material:  High-Strength Glazed Porcelain (Silicone Rubber Optional)

Origin:  China

Packaging:  Export Grade Reinforced Sea-Worthy Wooden Crates with 3D Impact Recorders

Delivery Time:  75-90 Days

Product Feature
LW30A-800 Y6300-63 High-Voltage AC SF6 Tank-Type Circuit Breaker
Product description
I. Application of LW30A-800 Y6300-63 800kV Live Tank Circuit Breaker in UHV Power Grids
The LW30A-800 Y6300-63 represents the pinnacle of heavy-duty utility switchgear engineered by Hengfengyou Electric for outdoor ultra-high voltage alternating current transmission networks. Designed to operate at a nominal voltage of 800kV, this porcelain-structured live tank circuit breaker provides indispensable overcurrent protection, short-circuit interruption, and routine system switching. It is specifically built for regional main grids, massive power plant step-up substations, and large-scale cross-border power interconnections where grid stability cannot be compromised.
With a monumental continuous current rating and an ultimate short-circuit breaking capacity of 63kA, this apparatus effectively shields expensive downstream substation assets, such as power transformers and shunt reactors, from catastrophic electrical grid faults. It fully aligns with international utility design criteria and delivers highly efficient arc-quenching performance under heavy load conditions.
II. Advanced SF6 High Voltage Breaker Design and Self-Blast Arc Extinguishing Technology
At the heart of the LW30A-800 circuit breaker is an advanced self-blast SF6 gas dynamic mechanism. By optimizing the internal gas flow channels and capitalizing on the thermal energy generated by the electrical arc itself, the breaker requires significantly less mechanical operating energy from its hydraulic mechanism. This dual-flow interrupter design drastically increases the speed of contact separation and arc extinguishment, resulting in exceptional electrical life and minimal contact erosion during fault clearance.
The primary structural layout utilizes premium mechanical materials designed to withstand extreme structural stresses. The heavy-duty operating mechanism is perfectly calibrated to ensure synchronized three-phase operation or single-phase rapid auto-reclosing sequences, meeting the rigorous dynamic response demands of modern transmission grids.
III. 6300A AC Circuit Breaker Environmental Resilience and Low Maintenance Features
Engineered for reliable operation in hostile outdoor environments, the breaker features high-strength insulation structures that possess excellent anti-pollution, anti-condensation, and high-saline resistance. The external housing is designed to withstand severe wind loads and violent seismic forces, making it suitable for desert, coastal, and high-altitude locations.
To minimize operational downtime, the breaker is equipped with a high-precision SF6 gas monitoring network. Featuring built-in temperature compensation and multi-stage density alarm contacts, the system tracks gas pressure in real time. Combined with an advanced double-sealing structure that limits the annual leakage rate to well under international thresholds, the LW30A-800 delivers a virtually maintenance-free solution that significantly extends standard overhaul intervals.
IV. 63kA Short Circuit Breaking Capacity Testing and Ultra-High Voltage Switchgear Standards
Hengfengyou Electric applies a rigorous quality control framework to all high-voltage apparatus. The LW30A-800 circuit breaker undergoes extensive type testing and routine factory acceptance tests to verify insulation levels, circuit resistance, gas tightness, and mechanical operating times. We support full third-party witness testing by globally recognized independent testing authorities to ensure seamless grid integration and compliance with international utility tenders.
Recognizing the logistical challenges of transporting ultra-high voltage equipment, all modules are shipped under secure positive pressure gas filling and packed in reinforced heavy-lift maritime crates. Each shipment is fitted with three-dimensional impact recorders to monitor handling safety from our manufacturing base to the final project site. Our high-voltage engineering team provides comprehensive technical support for on-site installation, gas processing, and site acceptance testing.
V. FAQ: LW30A-800 High Voltage AC SF6 Live Tank Circuit Breaker Buying Guide
Q: How does the LW30A-800 breaker handle gas leakage and maintenance overhead in extreme climates? A: The breaker features a dual-seal structure reducing annual SF6 leakage to below 0.5 percent. Built-in temperature-compensated density monitors provide early warning alerts, ensuring stable operation from minus 40 to plus 55 degrees Celsius with minimal routine maintenance.
Q: Can this 800kV SF6 high voltage breaker pass international grid bidding audits? A: Yes. It fully complies with IEC 62271-100 and IEC 62271-1 standards. Hengfengyou Electric provides full factory type test reports and supports independent third-party witness testing by KEMA, SGS, or Bureau Veritas to clear international utility tender requirements.
Q: How do you guarantee the safety of the porcelain live tank structure during long-distance logistics? A: All heavy-duty components are shipped under positive pressure gas filling within reinforced maritime crates. Every shipment is equipped with three-dimensional impact recorders to track mechanical stresses during transit, ensuring the gear arrives at your substation site intact.
Q: What on-site technical support do you provide for installation and commissioning? A: We deploy senior high-voltage field engineers to handle or supervise on-site mechanical alignment, SF6 vacuum pumping, gas filling, and Site Acceptance Testing to guarantee safe grid connection.