HENGFENGYOU SUBSTATION Co., Ltd

HENGFENGYOU SUBSTATION Co., Ltd

sales@hfy-substation.com

+86 158 0639 8816

Home > Product > Gas-Insulated Switchgear > >252kV Gas-Insulated Switchgear (GIS)

252kV Gas-Insulated Switchgear (GIS)

Payment Type:
L/C,T/T
Incoterm:
FOB,CFR,CIF
Min. Order:
1 Set/Sets
Delivery Time:
30 Days
Transportation:
Ocean,Land,Air
  • Product Description
Overview
Product Attributes

Model No.ZF12-252 / HGIS-252

BrandHENGFENGYOU

ApplicationPower distribution

PhaseSingle-phase Enclosure (Standard for 252kV)

Rated Voltage252kV

Rated current3150A / 4000A

Frequency50Hz / 60Hz

Degree of protectionIP67 (Gas Compartment)

StandardIEC 62271-203

CertificateCB CCC SABS

Shell MaterialSteel

OriginChina

PackagingPlywood

Delivery Time30 Days

Product Feature
Product description
Product Overview
The 252kV Gas-Insulated Switchgear (GIS) serves as the critical cornerstone for provincial hubs and backbone power grids. Engineered for high-voltage transmission networks, this system provides a High Interrupting Capacity to manage massive short-circuit currents while maintaining the highest levels of system stability and reliability under extreme grid stress.
Key Features
High Interrupting Capacity: Designed with advanced arc-quenching technology, it is capable of clearing severe faults in backbone networks with absolute precision and speed.
Superior Environmental Resilience: Specifically optimized for harsh conditions, including high-altitude plateaus and high-salt spray coastal zones, ensuring consistent performance where traditional air-insulated gear fails.
Aluminum Alloy Enclosure: The high-grade Aluminum Alloy Enclosure offers exceptional natural corrosion resistance and significantly reduces eddy current losses, extending the equipment's service life beyond 30 years.
Ultra-Low Leakage Rate: Utilizing advanced sealing technology, the system guarantees an annual Gas Leakage Rate of $\le$ 0.1%, meeting the "Life-long Sealing" quality benchmark.
Double-break Structure Option: For critical nodes requiring enhanced isolation security, we offer a Double-break structure configuration to provide redundant safety during maintenance and network switching.

Technical Specification
Parameter Specification
Rated Voltage 252kV
Rated Current 3150A / 4000A
Rated Breaking Current 40kA / 50kA
Annual Gas Leakage Rate ≤ 0.1%
Mechanical Endurance 10,000 Operations (M2 Class)
Application Environment
Provincial Hub Substations: The core switching authority for 252kV backbone transmission lines.
Extreme Altitude Projects: Reliable dielectric strength maintained in low-pressure environments above 3000m.
Offshore & Coastal Wind Hubs: The Aluminum Alloy shell prevents salt-air corrosion, making it the top choice for maritime energy landing points.
Heavy Industrial Infrastructure: Provides uncompromising power security for massive smelting plants and national-level manufacturing bases.

Why Choose Us (HENGFENGYOU ELECTRIC)
Backbone Grid Expertise: Our 252kV GIS is designed to meet the rigorous demands of national power authorities, focusing on "Zero Failure" operational philosophy.
Modular Engineering: Despite its high voltage rating, the Modular Design allows for efficient transport and Rapid on-site assembly, significantly reducing civil construction time.
Rigorous Testing: Every unit undergoes exhaustive partial discharge and impulse voltage testing in our state-of-the-art labs before shipment.

FAQ
1. Is this 252kV unit suitable for high-altitude regions?
Yes. By optimizing the internal gas pressure and external insulation distances, our 252kV GIS is engineered to operate reliably in high-altitude regions without derating.
2. What is the benefit of the Double-break structure?
The double-break option provides an additional layer of physical isolation. It is particularly valued by grid operators for critical hub substations where a "visible" and redundant gap is required for maximum maintenance safety.
3. How does the Aluminum Alloy enclosure improve efficiency?
Unlike steel, aluminum is non-magnetic. This prevents the generation of eddy currents when high currents pass through the conductors, reducing heat generation and saving significant amounts of energy over the life of the substation.
4. What kind of maintenance does a 252kV GIS require?
Due to the sealed-for-life design and the $\le$ 0.1% leakage rate, primary maintenance is minimal. It mainly involves periodic infrared thermography and remote monitoring of the gas density gauges.
Email to this supplier
  • *To:
    Mr. Hengfengyou
  • *name:
  • *email:
  • *Message:
    Your message must be between 20-8000 characters
Home Products Power Transformer Power Transformer Up To 132kv 50MVA 115/38.5KV 3 phase oil immersed power transformer
Related Products List

Home

Product

Phone

About Us

Inquiry