  • Product Description
Overview
Product Attributes

Model No.ZH1-126 / ZH1-252

BrandHENGFENGYOU

ApplicationPower distribution

PhaseSingle-phase or Three-phase Enclosure

Rated Voltage110kV / 126kV / 252kV

Rated current1250A / 2000A / 3150A

Frequency50Hz

Degree of protectionIP67 (Gas Compartment) / IP55 (Mechanism)

StandardIEC 62271-205

CertificateCB CCC SABS

Shell MaterialSteel

OriginChina

PackagingPlywood

Delivery Time30 Days

Product Feature
110kV-252kV Hybrid Gas-Insulated Switchgear (H-GIS)
Product description
Product Overview
The Hybrid Gas-Insulated Switchgear (H-GIS) is a versatile and innovative solution designed to bridge the gap between traditional Air-Insulated Switchgear (AIS) and full Gas-Insulated Switchgear (GIS). By integrating core switching components into a gas-insulated enclosure while utilizing air-insulated busbars, H-GIS provides a highly adaptable platform for power system upgrades and substation expansions.
Key Features
Retrofit Optimization: Specifically engineered for the modernization of existing substations, allowing for the replacement of aging AIS equipment with compact, high-performance gas-insulated modules without rebuilding the entire facility.
Hybrid Technology Advantages: Combines the superior reliability and environmental protection of GIS at the component level with the accessibility and lower busbar costs of AIS, striking the perfect balance between performance and investment.
Modular Integration: Featuring a flexible Modular integration approach, the H-GIS can be customized to include circuit breakers, disconnectors, and earthing switches within a single SF6-insulated housing tailored to specific site layouts.
Exceptional Cost-effectiveness: Offers significant savings in capital expenditure compared to a full GIS installation, as it utilizes existing outdoor busbar structures while providing the compact footprint and reduced maintenance of gas-insulated technology.
Rapid On-site Implementation: The factory-tested, compact modules allow for Rapid on-site assembly, drastically minimizing the downtime required for substation brownfield projects.

Technical Specification
Parameter Specification
Rated Voltage 110kV - 252kV
Rated Current 1250A / 2000A / 3150A
Rated Breaking Current 31.5kA / 40kA
Annual Gas Leakage Rate ≤0.1%
Mechanical Endurance 10,000 Operations (M2 Class)
Application Environment
Substation Retrofitting: The primary choice for upgrading old 110kV/220kV AIS substations where space for expansion is limited but a full GIS conversion is not budget-justified.
Flexible Capacity Expansion: Ideal for adding new feeders to existing power hubs where the original switchyard footprint cannot accommodate traditional equipment.
Industrial Site Upgrades: Provides a reliable and compact switching solution for factories or mining sites needing to increase power capacity within fixed infrastructure constraints.
Extreme Weather Protection: Protects critical switching elements from salt spray or heavy industrial pollution while maintaining a cost-effective outdoor busbar arrangement.

Why Choose Us (HENGFENGYOU ELECTRIC)
Flexibility Specialists: We excel at creating custom H-GIS configurations that fit perfectly into the unique physical constraints of older substations.
Smart Hybrid Engineering: Our team integrates decades of AIS and GIS expertise to ensure seamless compatibility between new gas-insulated modules and your existing air-insulated infrastructure.
Global Project Experience: HENGFENGYOU has successfully delivered H-GIS solutions for complex brownfield projects in over 50 countries, ensuring reliable power during the transition.

FAQ
1. How does H-GIS help in "Retrofit" projects?
H-GIS allows you to replace a large, high-maintenance AIS breaker and its surrounding disconnectors with one single, compact H-GIS module. This frees up space in the existing yard for other equipment or capacity increases.
2. Is H-GIS as reliable as a full GIS?
For the core switching functions, yes. The circuit breakers and disconnectors are housed in the same hermetically sealed SF6 environment as a full GIS, protecting them from environmental wear and ensuring an annual leakage rate of $\le$ 0.1%.
3. Why is H-GIS considered more "Cost-effective"?
Full GIS requires expensive gas-insulated busbars and housing for the entire station. H-GIS only insulates the core "moving parts," allowing you to use standard, inexpensive air-insulated conductors for the rest of the yard.
4. Can H-GIS modules be expanded in the future?
Yes. Due to the Modular integration design, additional modules can be added to the existing H-GIS lineup as your power demands grow, making it a future-proof investment.
Email to this supplier
  • *To:
    Mr. Hengfengyou
  • *name:
  • *email:
  • *Message:
    Your message must be between 20-8000 characters
Home Products Power Transformer Power Transformer Up To 132kv 50MVA 115/38.5KV 3 phase oil immersed power transformer
Related Products List

Home

Product

Phone

About Us

Inquiry