  • Product Description
Overview
Product Attributes

Model No.:  LW30-252 (T) 4000-50

Brand:  HENGFENGYOU

Application:  Dead Tank Transmission Network Protection and Current Interruption

Phase:  Three-phase

Rated Voltage:  252 kV

Rated current:  4000 A

Frequency:  50Hz / 60Hz

Degree of protection:  IP55 for Local Control Terminal

Standard:  IEC 62271-100, IEC 62271-1

Certificate:  ISO9001, ISO14001, CE, KEMA Type Tested

Shell Material:  Heavy-Duty Reinforced Steel Dead Tank Enclosure

Origin:  China

Packaging:  Heavy-Frame Industrial Shipping Skids with Tri-Axial Vibration Logging

Delivery Time:  75-90Days

Product Feature
LW30-252 (T) Circuit Breaker, 252kV Dead Tank Circuit Breaker, SF6 High Voltage Breaker, 4000A AC Circuit Breaker, 50kA Short Circuit Breaking, High Voltage Switchgear
Product description
I. Application of LW30-252 (T) 4000-50 252kV Dead Tank Circuit Breaker in High-Voltage Substation Networks
The LW30-252 (T) 4000-50 represents a highly reliable, low-profile safety architecture developed by Hengfengyou Electric for outdoor high-voltage electrical distribution networks. Engineered specifically around a grounded dead tank configuration, this 252kV SF6 switchgear handles primary circuit connection, automatic fault clearance, and overhead transmission line protection. It is widely adopted in dense urban substations, heavy mining operations, and regional transmission hubs where low center-of-gravity installation and high seismic resistance are paramount engineering mandates.
With a substantial 4000A continuous current capacity and a verified short-circuit current breaking performance of 50kA, this breaker isolates violent grid disruptions within milliseconds. The dead tank engineering accommodates low-mounted current transformers directly on the bushings, shielding vital substation machinery like reactors and step-down units from sudden voltage surges.
II. Advanced SF6 High Voltage Breaker Design and Self-Blast Arc Extinguishing Technology
The exceptional switching capability of the LW30-252 (T) circuit breaker relies on a localized thermal self-blast SF6 dynamic interrupter system. By focusing the high temperature and gas expansion generated by the fault arc inside a compact metal tank, the breaker quenches the electrical arc using minimized physical energy. This significantly lowers the driving force required from the integrated spring operating mechanism, lowering mechanical stress and preventing contact erosion over thousands of operational cycles.
The dead tank layout places the arc-extinguishing chambers inside a grounded metal container filled with SF6 gas, providing excellent dielectric shielding. The robust mechanical linkages are precisely synchronized to support rapid single-pole reclosing or synchronous three-pole gang-tripping, meeting the rigid clearing timelines of international power utilities.
III. 4000A AC Circuit Breaker Environmental Resilience and Low Maintenance Features
Built to withstand severe physical environments, the grounded steel tank housing provides outstanding structural shielding against heavy wind loading, falling debris, and high-intensity seismic movements. The external bushings feature high-creepage glazed porcelain or composite materials that resist surface flashovers in highly polluted chemical industrial belts, desert sands, or salty coastal atmospheres.
To minimize preventative on-site intervention and lower life-cycle costs, the breaker uses a high-performance double-O-ring sealing arrangement. Electronic gas density monitors paired with built-in temperature compensation provide constant real-time gas tracking. With a guaranteed annual leakage rate under 0.5 percent, the LW30-252 (T) provides regional utilities with an incredibly stable platform that stretches maintenance intervals.
IV. 50kA Short Circuit Breaking Capacity Testing and High Voltage Switchgear Standards
Quality tracking is integrated into every stage of the assembly process at Hengfengyou Electric. The LW30-252 (T) circuit breaker passes thorough type-test validation and routine factory screening covering impulse voltage insulation, contact resistance, gas envelope integrity, and mechanical operational alignment. We fully accommodate international utility procurement criteria by supporting independent third-party inspections and witness testing handled by firms like KEMA, SGS, or Bureau Veritas.
To prevent structural shifting during ocean transit, the dead tank units are bolted securely onto heavy steel shipping frames. Electronic shock-logging devices are mounted to the packing layout to log handling stresses from our production shop to the project destination. Our field deployment teams provide complete technical support for on-site placement, vacuum drying, SF6 gas processing, and final Site Acceptance Testing.
V. FAQ: LW30-252 (T) High Voltage AC SF6 Dead Tank Circuit Breaker Buying Guide
Q: What are the primary structural advantages of the LW30-252 (T) dead tank design compared to live tank models?
A: The dead tank configuration features a grounded metal enclosure containing the interrupters, which lowers the center of gravity for superior seismic performance. Additionally, it allows current transformers to be mounted directly on the bushings, reducing overall footprint and substation civil construction costs.
Q: Is this 252kV SF6 high voltage breaker certified to pass utility grid bidding requirements?
A: Yes. It is fully certified to conform strictly to international specifications including IEC 62271-100 and IEC 62271-1. Full type-test files are kept on hand, and we support on-site validation by third-party inspection firms such as KEMA or SGS to verify compliance with tender rules.
Q: How does the breaker ensure zero gas leakage under high mechanical vibration?
A: The breaker utilizes specialized high-elasticity polymer dual-seal gaskets along all structural joints, keeping the annual leak rate well below 0.5 percent. Built-in temperature-compensated density monitors track internal gas levels continually from minus 40 up to plus 55 degrees Celsius.
Q: What on-site technical support do you provide for installation and commissioning?
A: We deploy senior high-voltage field engineers to handle or supervise on-site mechanical alignment, current transformer wiring, SF6 vacuum processing, gas filling, and Site Acceptance Testing to guarantee safe grid connection.