Model No.:  LW30-252

Brand:  HENGFENGYOU

Application:  Overhead Line Control and High Voltage Substation Protection

Phase:  Three-phase

Rated Voltage:  252 kV

Rated current:  3150 A / 4000 A (Configurable)

Frequency:  50Hz / 60Hz

Degree of protection:  IP55 for Spring Mechanism Box

Standard:  IEC 62271-100, IEC 62271-1

Certificate:  ISO9001, ISO14001, CE, KEMA Certified

Shell Material:  Structural Glazed Porcelain Column Assembly

Origin:  China

Packaging:  Reinforced Seaworthy Wooden Crates with Multi-Axis Shock Monitoring

Delivery Time:  75-90Days

Product Feature
LW30-252 Circuit Breaker, 252kV Porcelain Column Circuit Breaker, SF6 High Voltage Breaker, 3150A AC Circuit Breaker, 50kA Short Circuit Breaking, High Voltage Switchgear
Product description
I. Application of LW30-252 252kV Porcelain Column Circuit Breaker in Regional Transmission Lines
The LW30-252 stands as a classic, high-performance line switching solution engineered by Hengfengyou Electric for high-voltage open-air utility substations. Built using an elevated porcelain column structure, this 252kV SF6 gas circuit breaker handles high-capacity switching, fault clearance, and grid line segmentation. It serves as an essential protective barrier in standard terminal substations, industrial power injection nodes, and urban periphery transmission line layouts where clear physical isolation and vertical space utilization are prioritized.
Engineered to support a continuous current rating up to 4000A along with a short-circuit interrupting benchmark of 50kA, the breaker mitigates sudden electrical overloads seamlessly. This reliable clearing protects heavy grid components, including substation busbars and primary transformers, from experiencing damaging electro-dynamic forces during transmission faults.
II. Advanced SF6 High Voltage Breaker Design and Self-Blast Arc Extinguishing Technology
The exceptional operational safety of the LW30-252 circuit breaker relies on an advanced single-pressure thermal self-blast gas interrupter system. By maximizing gas compression efficiency within the upper porcelain columns during the open stroke, the breaker directs an intense SF6 gas stream straight through the arc path. This self-blast action requires very little driving energy from the primary spring operating mechanism, lowering mechanical impact wear and maintaining long contact longevity.
The high-profile porcelain column arrangement provides optimal phase-to-ground dielectric insulation clearance while keeping the base installation footprint small. The operating shafts are perfectly calibrated to achieve tight mechanical synchronization across all three phases, ensuring rapid single-phase auto-reclosing patterns that fulfill modern grid safety standards.
III. 3150A/4000A AC Circuit Breaker Environmental Resilience and Low Maintenance Features
Engineered to operate continuously under unpredictable outdoor weather parameters, the breaker features premium glazed porcelain columns that offer extensive creepage distances and excellent anti-tracking performance under severe soot or saline buildup. The structural steel support frame is hot-dip galvanized to resist rusting in damp, high-humidity river basins, agricultural plains, or coastal environments.
To eliminate frequent field adjustments and lower total asset operational costs, the breaker uses a proven low-leakage gas control system. Integrated dual-contact density switches with temperature-compensated tracking provide constant gas pressure reporting. Backed by high-integrity sealing materials that cap the annual gas escape rate below 0.5 percent, the LW30-252 ensures long, uninterrupted operational windows with minimal routine field service.
IV. 50kA Short Circuit Breaking Capacity Testing and High Voltage Switchgear Standards
Quality control is strictly managed across the entire assembly layout at Hengfengyou Electric. Every individual LW30-252 porcelain column breaker passes comprehensive factory test protocols, including impulse withstand testing, loop resistance checking, SF6 gas tightness audits, and mechanical timing performance profiling. We fully support international procurement processes by opening our factory to technical inspections and witness testing managed by independent testing authorities like KEMA, SGS, or Bureau Veritas.
To safeguard the delicate vertical porcelain components during overseas ocean transport, the modules are shipped under a positive pressure gas cushion within heavy-framed wooden crates. Impact-sensitive recording devices are mounted directly inside the crates to monitor transit handling safety from our factory floor to your substation yard. Our field technical teams stand ready to manage on-site structural assembly, vacuum cycle processing, gas filling, and Site Acceptance Testing.
V. FAQ: LW30-252 High Voltage AC SF6 Porcelain Column Circuit Breaker Buying Guide
Q: What makes the LW30-252 porcelain column breaker ideal for standard open-air substations?
A: The porcelain column structure provides excellent vertical phase-to-ground insulation clearing while minimizing the base ground footprint. This makes it very cost-effective for classic outdoor substations where space optimization at ground level is desired.
Q: Does this 252kV SF6 high voltage breaker meet international bidding specifications?
A: Yes. It is manufactured and type-tested in strict compliance with IEC 62271-100 and IEC 62271-1 standards. Certified test documentation is available, and we support independent third-party witness inspections by KEMA or Bureau Veritas to satisfy tender protocols.
Q: How does the breaker perform in high-humidity or corrosive industrial zones?
A: The structural steel frames are treated with deep hot-dip galvanization, and the porcelain columns are glazed to prevent surface tracking. All control enclosures feature IP55 water and dust protection along with anti-condensation heaters to ensure reliable operation.
Q: What technical commissioning assistance does Hengfengyou Electric offer post-delivery?
A: We provide complete technical oversight by dispatching certified high-voltage field technicians to your site to guide structural installation, manage vacuum pumping and SF6 filling, and perform the final Site Acceptance Testing to achieve a safe grid connection.
Email to this supplier
  • *To:
    Mr. Hengfengyou
  • *name:
  • *email:
  • *Message:
    Your message must be between 20-8000 characters
Home Products Power Transformer Power Transformer Up To 132kv 50MVA 115/38.5KV 3 phase oil immersed power transformer
Related Products List

Home

Product

Phone

About Us

Inquiry